ALTAIR 4X

New product

Building on years of sensor design experience, MSA is revolutionising sensor technology with breakthroughs in design that improve performance.

With reliable, extended-life XCell Sensors, there’s no need to replace sensors after two years.

More details

More info

  • Sensor response and clear times under 15 seconds 

  • Bump test under 15 seconds 

  • Span calibration time under 60 seconds 

  • Greater signal stability and repeatability under changing or extreme environmental conditions 

  • Two-tox CO/H2S sensor with virtually no cross-channel interference 

  • The digital output of the sensors makes them much less susceptible to RF interference
  • Typical life greater than four year
  • Laser-welded sensor housings eliminate opportunities for leaks
  • Proprietary operating mode of the combustible sensor helps it stand up to poisons over the life of the sensor
  • End-of-sensor-life indicator gives advanced warning to the user, eliminating service outages
  • Large buttons and a bright display enable quick and easy operation even while wearing gloves 

  • If a user becomes disabled due to unforeseen hazards, the Motion Alert sensor will activate after 30 seconds 

  • The Instant Alert feature enables users to manually alert others of a dangerous situation with the push of a button 

  • Compatible with GALAXY Test System and ALTAIR4 Quick Check Station 

  • MSA Link Software-ready 

  • Global approvals for worldwide acceptance


Technical Specications


Drop test : 6m

Housing : 
Rugged rubberised armour


Weight : 222 g


Dimensions (H x W x D) : 112 x 76 x 35 mm

Audible alarm :  >95 dB at 30 cm


Visual alarm : 4 ultra-bright LEDs on top and bottom

Vibrating alarm :  Standard


MotionAlert & InstantAlert :  Standard 

Display : High-contrast LCD

Backlight : Adjustable time-out 

Battery : Rechargeable li-polymer


Run time : 24 hour @
room temperature

Charging time : < 4 hrs


Operating temperature range : –20°C to +50°C

Short period operation : –40°C to +60°C

Humidity : 15–90% RH non-condensing

Ingress protection : IP 67

Data log : Standard, 50 hours minimum


Event log :Standard 500 events

Standard warranty : 3 years


Extended warranty : Optional 1 year 
     



Approvals
 ATEX:

II 1G Ex ia IICT4, –40°C to +60°C, IP67
(Zone 0 with no combustible sensor installed) II 2G Ex ia d IIC T4, –40 °C to +60°C, IP 67 (Zone 1 with combustible sensor installed)


1 other product in the same category: